Starting method of cold heading machine

As forCold heading machineThe cold heading machine manufacturer here will give you a detailed introduction, hoping that it can help you better understand the cold heading machine and use it correctly. The cold heading machine manufacturer will take you to know:

1. Emergency stop and hold: Press the emergency stop button on the control cabinet operation panel and the equipment stops running. Pull off the total power supply and the data on the counter remains unchanged. After the power is re-sending, the equipment then processes the parts until it reaches the preset number.

2. Parameter setting: According to the requirements of the user unit, by setting the acceleration and deceleration time parameters, the time required for the inverter startup frequency to increase from 1Hz to 50Hz is set to 3s.

3. Processing test: First start the equipment to process parts in manual mode. The equipment runs correctly and change to automatic mode. Set the total number of processing parts to 30 pieces on the counter to start the equipment. When the processing number reaches 30 pieces, the equipment stops running.

4. Hardware field connection. Install the proximity switch on the device and connect various components according to the electrical schematic.

5. Reset: Press the two reset switches on the counter operation panel to reset the preset number and processing number respectively.

6. Key protection: After the cold heading machine and the key switch (SA1) are rotated, the key operation on the counter operation panel fails.